States ›Texas ›Hidalgo County ›Alton

Alton, TX Tap Water Quality 2026

Water quality report for Alton, TX — PFAS, lead and copper results, violation history and state inspection findings from EPA SDWIS.

A look at Alton's drinking water using EPA enforcement records: violations, lead and copper results, PFAS sampling and state inspection findings.

Main Utility: Sharyland Wsc PWSID: TX1080033 Updated: 2026 Q2
✅

No federal limits exceeded on record

Lead is 1.00 ppb, 7% of the action level and no violations are open. PFAS was detected below the federal limit.

A

Alton earns an A for water quality

Graded on violations, lead, and PFAS, with state inspection findings.

Lead: 1.00 ppb — 7% of the federal action level
PFAS detected below the federal limit
3 violations since 2015, 2 health-based
No violations currently open
Alton's lead level vs. all Texas community water systems
0 ppb5 ppb10 ppb15 ppb
Lead level: 1.00 ppb — 7% of the federal action level
✓ Lower lead than 83% of Texas utilities
Population Served
18188
~22854 connections
Water Source
Surface water
Drawn from surface water — SDWIS source code SW
Active Violations
0
3 since 2015, all resolved

Lead & Copper Testing

Lead (Pb)
90th percentile of tap samples collected across the distribution system
7% of EPA action level
1.00 ppb
Action level: 15 ppb
The 90th-percentile lead result is 1.00 ppb, 7% of the 15 ppb federal action level. The action level is a treatment trigger, not a legal maximum, and it is measured across sampled taps rather than at any single home.

Contaminant Violations (2015–Present)

ContaminantTypeMeasuredLimitPeriodStatus
Chlorite MCL EXCEEDANCE 1.4 MG/L 1.0 mg/L 2019 Resolved
Chlorite MONITORING AND REPORTING — 1.0 mg/L 2018 Resolved
Coliform (TCR) MCL EXCEEDANCE — 5% of samples 2015 Resolved
Understanding violation types MCL violations mean a contaminant exceeded the federal maximum limit — the most serious type.
TT (Treatment Technique) violations mean required treatment procedures weren't followed, but don't necessarily mean contamination occurred.

Violation History

3 violations are on record since 2015, of which 2 were health-based. All have been resolved and none remain open.

About the Main Water System

Utility Sharyland Wsc
PWSID TX1080033
Water source Surface water — Drawn from surface water — SDWIS source code SW
Population served 18,188
Service connections 22,854
Systems serving this area 1
Regulator State primacy agency
Data through 2026 Q2 — EPA SDWIS

Frequently Asked Questions

Is Alton tap water safe to drink? ▼
No federal limit is exceeded on record. No violations are currently open. Lead is 1.00 ppb, 7% of the action level.
Does Alton water have PFAS? ▼
PFAS was detected but stayed below the federal limit.
Who supplies water to Alton? ▼
Sharyland Wsc (PWSID TX1080033). Surface water. Drawn from surface water — SDWIS source code SW
When was this system last inspected? ▼
It was last inspected on 2025-09-26. No significant deficiencies were recorded.

What Should Alton Residents Do?

1
Read your annual water report
Your supplier publishes a Consumer Confidence Report each July covering the prior year.
2
Check for a lead service line
Lead reaches tap water mainly through service lines and household plumbing. Suppliers now publish an inventory identifying lead lines.
3
Flush before drinking
If water has sat in pipes more than six hours, run the cold tap for two minutes before drinking or cooking.

Nearby Cities in Texas

McAllen, Tx Tap Water Quality 2026 Hidalgo Mission, Tx Tap Water Quality 2026 Hidalgo Pharr, Tx Tap Water Quality 2026 Hidalgo Edinburg, Tx Tap Water Quality 2026 Hidalgo Weslaco, Tx Tap Water Quality 2026 Hidalgo San Juan, Tx Tap Water Quality 2026 Hidalgo