States ›Oklahoma ›Lincoln County ›Warwick

Warwick, OK Tap Water Quality 2026

Water quality report for Warwick, OK — PFAS, lead and copper results, violation history and state inspection findings from EPA SDWIS.

A look at Warwick's drinking water using EPA enforcement records: violations, lead and copper results, PFAS sampling and state inspection findings.

Main Utility: Lincoln Co Rwd #3 PWSID: OK3004107 Updated: 2026 Q2
✅

No federal limits exceeded on record

Lead is 5.70 ppb, 38% of the action level and no violations are open. PFAS has never been sampled at this system.

C

Warwick earns a C for water quality

Graded on violations and lead, with state inspection findings. PFAS not tested.

Lead: 5.70 ppb — 38% of the federal action level
PFAS never sampled at this system
26 violations since 2015, 21 health-based
No violations currently open
Warwick's lead level vs. all Oklahoma community water systems
0 ppb5 ppb10 ppb15 ppb
Lead level: 5.70 ppb — 38% of the federal action level
✓ Lower lead than 14% of Oklahoma utilities
Population Served
164
~230 connections
Water Source
Surface water
Purchased from another system — SDWIS source code SWP
Active Violations
0
26 since 2015, all resolved

Lead & Copper Testing

Lead (Pb)
90th percentile of tap samples collected across the distribution system
38% of EPA action level
5.70 ppb
Action level: 15 ppb
Copper (Cu)
90th percentile of tap samples. SDWIS reports a copper figure only when a system exceeds the action level, so any value here is an exceedance.
121.5% of EPA action level
1,580 ppb
Action level: 1,300 ppb
The 90th-percentile lead result is 5.70 ppb, 38% of the 15 ppb federal action level. The action level is a treatment trigger, not a legal maximum, and it is measured across sampled taps rather than at any single home. Copper reached the action level here; a copper figure appears in SDWIS only when a system triggers it.

Contaminant Violations (2015–Present)

ContaminantTypeMeasuredLimitPeriodStatus
LEAD AND COPPER RULE REVISIONS TREATMENT TECHNIQUE — — 2024 Addressed
LEAD AND COPPER RULE REVISIONS REPORTING FAILURE — — 2024 Addressed
Consumer Confidence Rule OTHER — — 2024 Resolved
TTHM MCL EXCEEDANCE 0.099 MG/L 0.080 mg/L 2023 Resolved
TTHM MCL EXCEEDANCE 0.083 MG/L 0.080 mg/L 2023 Resolved
TTHM MCL EXCEEDANCE 0.097 MG/L 0.080 mg/L 2022 Resolved
TTHM MONITORING AND REPORTING — 0.080 mg/L 2022 Resolved
TTHM MCL EXCEEDANCE 0.094 MG/L 0.080 mg/L 2022 Resolved
TTHM MCL EXCEEDANCE 0.091 MG/L 0.080 mg/L 2022 Resolved
TTHM MCL EXCEEDANCE 0.081 MG/L 0.080 mg/L 2020 Resolved
Chlorine MONITORING AND REPORTING — 4.0 mg/L 2019 Resolved
TTHM MCL EXCEEDANCE 0.085 MG/L 0.080 mg/L 2018 Resolved
TTHM MCL EXCEEDANCE 0.102 MG/L 0.080 mg/L 2018 Resolved
TTHM MCL EXCEEDANCE 0.113 MG/L 0.080 mg/L 2017 Resolved
TTHM MCL EXCEEDANCE 0.134 MG/L 0.080 mg/L 2017 Archived
TTHM MCL EXCEEDANCE 0.093 MG/L 0.080 mg/L 2017 Resolved
TTHM MCL EXCEEDANCE 0.1 MG/L 0.080 mg/L 2017 Resolved
Lead and Copper Rule MONITORING AND REPORTING — TT 2017 Resolved
TTHM MCL EXCEEDANCE 0.143 MG/L 0.080 mg/L 2016 Resolved
TTHM MCL EXCEEDANCE 0.155 MG/L 0.080 mg/L 2016 Resolved
TTHM MCL EXCEEDANCE 0.117 MG/L 0.080 mg/L 2016 Resolved
TTHM MCL EXCEEDANCE 0.157 MG/L 0.080 mg/L 2016 Resolved
TTHM MCL EXCEEDANCE 0.125 MG/L 0.080 mg/L 2015 Resolved
TTHM MCL EXCEEDANCE 0.111 MG/L 0.080 mg/L 2015 Resolved
TTHM MCL EXCEEDANCE 0.137 MG/L 0.080 mg/L 2015 Resolved
TTHM MCL EXCEEDANCE 0.135 MG/L 0.080 mg/L 2015 Resolved
Understanding violation types MCL violations mean a contaminant exceeded the federal maximum limit — the most serious type.
TT (Treatment Technique) violations mean required treatment procedures weren't followed, but don't necessarily mean contamination occurred.

Violation History

26 violations are on record since 2015, of which 21 were health-based. All have been resolved and none remain open.

About the Main Water System

Utility Lincoln Co Rwd #3
PWSID OK3004107
Water source Surface water — Purchased from another system — SDWIS source code SWP
Population served 164
Service connections 230
Systems serving this area 1
Regulator State primacy agency
Data through 2026 Q2 — EPA SDWIS

Frequently Asked Questions

Is Warwick tap water safe to drink? ▼
No federal limit is exceeded on record. No violations are currently open. Lead is 5.70 ppb, 38% of the action level.
Does Warwick water have PFAS? ▼
This system has never been sampled for PFAS. EPA's national monitoring covered systems serving 3,300 people or more, so no results exist — which is not evidence that none is present.
Who supplies water to Warwick? ▼
Lincoln Co Rwd #3 (PWSID OK3004107). Surface water. Purchased from another system — SDWIS source code SWP
When was this system last inspected? ▼
It was last inspected on 2025-06-18. No significant deficiencies were recorded.

What Should Warwick Residents Do?

1
Consider a filter certified for lead
Look for NSF/ANSI 53 certification for lead reduction.
2
Check for a lead service line
Lead reaches tap water mainly through service lines and household plumbing. Suppliers now publish an inventory identifying lead lines.
3
Flush before drinking
If water has sat in pipes more than six hours, run the cold tap for two minutes before drinking or cooking.

Nearby Cities in Oklahoma

Stroud, Ok Tap Water Quality 2026 Lincoln Prague, Ok Tap Water Quality 2026 Lincoln Chandler, Ok Tap Water Quality 2026 Lincoln Meeker, Ok Tap Water Quality 2026 Lincoln Davenport, Ok Tap Water Quality 2026 Lincoln Carney, Ok Tap Water Quality 2026 Lincoln