States ›Oklahoma ›Haskell County ›McCurtain

McCurtain, OK Tap Water Quality 2026

Water quality report for McCurtain, OK — PFAS, lead and copper results, violation history and state inspection findings from EPA SDWIS.

A look at McCurtain's drinking water using EPA enforcement records: violations, lead and copper results, PFAS sampling and state inspection findings.

Main Utility: Mccurtain Municipal Authority PWSID: OK3003101 Updated: 2026 Q2
✅

No federal limits exceeded on record

Lead was not detected and no violations are open. PFAS has never been sampled at this system.

B

McCurtain earns a B for water quality

Graded on violations and lead, with state inspection findings. PFAS not tested.

Lead: not detected
PFAS never sampled at this system
90 violations since 2015, 65 health-based
No violations currently open
McCurtain's lead level vs. all Oklahoma community water systems
0 ppb5 ppb10 ppb15 ppb
Lead level: Not detected — 0% of the federal action level
✓ Lower lead than % of Oklahoma utilities
Population Served
96
~270 connections
Water Source
Surface water
Purchased from another system — SDWIS source code SWP
Active Violations
0
90 since 2015, all resolved

Lead & Copper Testing

Lead (Pb)
90th percentile of tap samples collected across the distribution system
0% of EPA action level
Not detected
Action level: 15 ppb
Lead was not detected at the 90th percentile — the result fell below the laboratory detection limit. That is not the same as an absence of lead in every tap, and older homes with lead service lines can still show higher readings.

Contaminant Violations (2015–Present)

ContaminantTypeMeasuredLimitPeriodStatus
Total Haloacetic Acids (HAA5) MCL EXCEEDANCE 0.062 MG/L 0.060 mg/L 2025 Archived
Total Haloacetic Acids (HAA5) MCL EXCEEDANCE 0.065 MG/L 0.060 mg/L 2025 Archived
TTHM MCL EXCEEDANCE 0.081 MG/L 0.080 mg/L 2025 Archived
Total Haloacetic Acids (HAA5) MCL EXCEEDANCE 0.063 MG/L 0.060 mg/L 2025 Archived
LEAD AND COPPER RULE REVISIONS TREATMENT TECHNIQUE — — 2024 Addressed
LEAD AND COPPER RULE REVISIONS REPORTING FAILURE — — 2024 Addressed
TTHM MCL EXCEEDANCE 0.085 MG/L 0.080 mg/L 2024 Archived
TTHM MCL EXCEEDANCE 0.09 MG/L 0.080 mg/L 2024 Archived
TTHM MCL EXCEEDANCE 0.092 MG/L 0.080 mg/L 2024 Archived
TTHM MCL EXCEEDANCE 0.103 MG/L 0.080 mg/L 2023 Archived
Lead and Copper Rule MONITORING AND REPORTING — TT 2023 Resolved
TTHM MCL EXCEEDANCE 0.108 MG/L 0.080 mg/L 2023 Archived
TTHM MCL EXCEEDANCE 0.084 MG/L 0.080 mg/L 2023 Archived
TTHM MONITORING AND REPORTING — 0.080 mg/L 2023 Resolved
TTHM MCL EXCEEDANCE 0.113 MG/L 0.080 mg/L 2023 Archived
TTHM MCL EXCEEDANCE 0.098 MG/L 0.080 mg/L 2023 Archived
Lead and Copper Rule MONITORING AND REPORTING — TT 2023 Resolved
TTHM MCL EXCEEDANCE 0.103 MG/L 0.080 mg/L 2023 Archived
TTHM MCL EXCEEDANCE 0.112 MG/L 0.080 mg/L 2023 Archived
TTHM MCL EXCEEDANCE 0.105 MG/L 0.080 mg/L 2022 Archived
TTHM MCL EXCEEDANCE 0.103 MG/L 0.080 mg/L 2022 Archived
TTHM MCL EXCEEDANCE 0.1 MG/L 0.080 mg/L 2022 Archived
TTHM MCL EXCEEDANCE 0.098 MG/L 0.080 mg/L 2022 Archived
TTHM MONITORING AND REPORTING — 0.080 mg/L 2022 Resolved
TTHM MCL EXCEEDANCE 0.092 MG/L 0.080 mg/L 2022 Archived
TTHM MCL EXCEEDANCE 0.101 MG/L 0.080 mg/L 2022 Archived
TTHM MCL EXCEEDANCE 0.093 MG/L 0.080 mg/L 2022 Archived
TTHM MCL EXCEEDANCE 0.086 MG/L 0.080 mg/L 2022 Archived
TTHM MCL EXCEEDANCE 0.085 MG/L 0.080 mg/L 2021 Archived
TTHM MCL EXCEEDANCE 0.1 MG/L 0.080 mg/L 2021 Archived
TTHM MCL EXCEEDANCE 0.082 MG/L 0.080 mg/L 2021 Archived
TTHM MCL EXCEEDANCE 0.102 MG/L 0.080 mg/L 2021 Archived
TTHM MONITORING AND REPORTING — 0.080 mg/L 2021 Resolved
TTHM MCL EXCEEDANCE 0.099 MG/L 0.080 mg/L 2021 Archived
TTHM MCL EXCEEDANCE 0.09 MG/L 0.080 mg/L 2021 Archived
TTHM MCL EXCEEDANCE 0.097 MG/L 0.080 mg/L 2021 Archived
TTHM MCL EXCEEDANCE 0.115 MG/L 0.080 mg/L 2021 Archived
TTHM MCL EXCEEDANCE 0.112 MG/L 0.080 mg/L 2020 Archived
TTHM MCL EXCEEDANCE 0.103 MG/L 0.080 mg/L 2020 Archived
TTHM MCL EXCEEDANCE 0.104 MG/L 0.080 mg/L 2020 Archived
TTHM MCL EXCEEDANCE 0.107 MG/L 0.080 mg/L 2020 Archived
TTHM MCL EXCEEDANCE 0.112 MG/L 0.080 mg/L 2020 Archived
TTHM MCL EXCEEDANCE 0.101 MG/L 0.080 mg/L 2020 Archived
TTHM MCL EXCEEDANCE 0.102 MG/L 0.080 mg/L 2020 Archived
TTHM MCL EXCEEDANCE 0.091 MG/L 0.080 mg/L 2020 Archived
TTHM MCL EXCEEDANCE 0.108 MG/L 0.080 mg/L 2019 Archived
TTHM MCL EXCEEDANCE 0.091 MG/L 0.080 mg/L 2019 Archived
TTHM MONITORING AND REPORTING — 0.080 mg/L 2019 Resolved
TTHM MCL EXCEEDANCE 0.098 MG/L 0.080 mg/L 2019 Archived
TTHM MCL EXCEEDANCE 0.108 MG/L 0.080 mg/L 2019 Archived
TTHM MONITORING AND REPORTING — 0.080 mg/L 2019 Resolved
TTHM MCL EXCEEDANCE 0.095 MG/L 0.080 mg/L 2019 Archived
TTHM MCL EXCEEDANCE 0.095 MG/L 0.080 mg/L 2019 Archived
TTHM MCL EXCEEDANCE 0.11 MG/L 0.080 mg/L 2019 Archived
TTHM MCL EXCEEDANCE 0.113 MG/L 0.080 mg/L 2019 Archived
TTHM MCL EXCEEDANCE 0.111 MG/L 0.080 mg/L 2018 Archived
TTHM MCL EXCEEDANCE 0.107 MG/L 0.080 mg/L 2018 Archived
TTHM MONITORING AND REPORTING — 0.080 mg/L 2018 Resolved
TTHM MCL EXCEEDANCE 0.1 MG/L 0.080 mg/L 2018 Archived
TTHM MCL EXCEEDANCE 0.117 MG/L 0.080 mg/L 2018 Archived
TTHM MCL EXCEEDANCE 0.13 MG/L 0.080 mg/L 2018 Archived
TTHM MCL EXCEEDANCE 0.097 MG/L 0.080 mg/L 2018 Archived
TTHM MONITORING AND REPORTING — 0.080 mg/L 2017 Resolved
TTHM MCL EXCEEDANCE 0.095 MG/L 0.080 mg/L 2017 Archived
TTHM MONITORING AND REPORTING — 0.080 mg/L 2017 Resolved
Consumer Confidence Rule OTHER — — 2017 Resolved
TTHM MCL EXCEEDANCE 0.097 MG/L 0.080 mg/L 2017 Archived
TTHM MONITORING AND REPORTING — 0.080 mg/L 2017 Resolved
TTHM MCL EXCEEDANCE 0.118 MG/L 0.080 mg/L 2017 Archived
TTHM MCL EXCEEDANCE 0.12 MG/L 0.080 mg/L 2017 Archived
TTHM MCL EXCEEDANCE 0.092 MG/L 0.080 mg/L 2016 Archived
Consumer Confidence Rule OTHER — — 2016 Resolved
TTHM MCL EXCEEDANCE 0.094 MG/L 0.080 mg/L 2016 Archived
TTHM MONITORING AND REPORTING — 0.080 mg/L 2016 Resolved
TTHM MCL EXCEEDANCE 0.141 MG/L 0.080 mg/L 2016 Archived
TTHM MONITORING AND REPORTING — 0.080 mg/L 2016 Resolved
Lead and Copper Rule MONITORING AND REPORTING — TT 2016 Resolved
TTHM MCL EXCEEDANCE 0.103 MG/L 0.080 mg/L 2016 Archived
TTHM MONITORING AND REPORTING — 0.080 mg/L 2015 Resolved
Total Haloacetic Acids (HAA5) MONITORING AND REPORTING — 0.060 mg/L 2015 Resolved
Chlorine MONITORING AND REPORTING — 4.0 mg/L 2015 Archived
TTHM MCL EXCEEDANCE 0.139 MG/L 0.080 mg/L 2015 Archived
TTHM MONITORING AND REPORTING — 0.080 mg/L 2015 Resolved
Lead and Copper Rule MONITORING AND REPORTING — TT 2015 Resolved
Chlorine MONITORING AND REPORTING — 4.0 mg/L 2015 Archived
TTHM MCL EXCEEDANCE 0.098 MG/L 0.080 mg/L 2015 Archived
TTHM MONITORING AND REPORTING — 0.080 mg/L 2015 Resolved
TTHM MCL EXCEEDANCE 0.106 MG/L 0.080 mg/L 2015 Archived
Lead and Copper Rule MONITORING AND REPORTING — TT 2015 Resolved
TTHM MCL EXCEEDANCE 0.117 MG/L 0.080 mg/L 2015 Archived
Understanding violation types MCL violations mean a contaminant exceeded the federal maximum limit — the most serious type.
TT (Treatment Technique) violations mean required treatment procedures weren't followed, but don't necessarily mean contamination occurred.

Violation History

90 violations are on record since 2015, of which 65 were health-based. All have been resolved and none remain open.

About the Main Water System

Utility Mccurtain Municipal Authority
PWSID OK3003101
Water source Surface water — Purchased from another system — SDWIS source code SWP
Population served 96
Service connections 270
Systems serving this area 1
Regulator State primacy agency
Data through 2026 Q2 — EPA SDWIS

Frequently Asked Questions

Is McCurtain tap water safe to drink? ▼
No federal limit is exceeded on record. No violations are currently open.
Does McCurtain water have PFAS? ▼
This system has never been sampled for PFAS. EPA's national monitoring covered systems serving 3,300 people or more, so no results exist — which is not evidence that none is present.
Who supplies water to McCurtain? ▼
Mccurtain Municipal Authority (PWSID OK3003101). Surface water. Purchased from another system — SDWIS source code SWP
When was this system last inspected? ▼
It was last inspected on 2024-07-15. No significant deficiencies were recorded.

What Should McCurtain Residents Do?

1
Read your annual water report
Your supplier publishes a Consumer Confidence Report each July covering the prior year.
2
Check for a lead service line
Lead reaches tap water mainly through service lines and household plumbing. Suppliers now publish an inventory identifying lead lines.
3
Flush before drinking
If water has sat in pipes more than six hours, run the cold tap for two minutes before drinking or cooking.

Nearby Cities in Oklahoma

Stigler, Ok Tap Water Quality 2026 Haskell Whitefield, Ok Tap Water Quality 2026 Haskell Kinta, Ok Tap Water Quality 2026 Haskell Keota, Ok Tap Water Quality 2026 Haskell Enterprise, Ok Tap Water Quality 2026 Haskell Tamaha, Ok Tap Water Quality 2026 Haskell