States ›New York ›Washington County ›Whitehall

Whitehall, NY Tap Water Quality 2026

Water quality report for Whitehall, NY — PFAS, lead and copper results, violation history and state inspection findings from EPA SDWIS.

A look at Whitehall's drinking water using EPA enforcement records: violations, lead and copper results, PFAS sampling and state inspection findings.

Main Utility: Whitehall Village PWSID: NY5700124 Updated: 2026 Q2
✅

No federal limits exceeded on record

Lead is 5.60 ppb, 37% of the action level and no violations are open. PFAS has never been sampled at this system.

C

Whitehall earns a C for water quality

Graded on violations and lead, with state inspection findings. PFAS not tested.

Lead: 5.60 ppb — 37% of the federal action level
PFAS never sampled at this system
43 violations since 2015, 9 health-based
No violations currently open
Whitehall's lead level vs. all New York community water systems
0 ppb5 ppb10 ppb15 ppb
Lead level: 5.60 ppb — 37% of the federal action level
✓ Lower lead than 20% of New York utilities
Population Served
2363
~1432 connections
Water Source
Surface water
Drawn from surface water — SDWIS source code SW
Active Violations
0
43 since 2015, all resolved

Lead & Copper Testing

Lead (Pb)
90th percentile of tap samples collected across the distribution system
37% of EPA action level
5.60 ppb
Action level: 15 ppb
Copper (Cu)
90th percentile of tap samples. SDWIS reports a copper figure only when a system exceeds the action level, so any value here is an exceedance.
130.8% of EPA action level
1,700 ppb
Action level: 1,300 ppb
The 90th-percentile lead result is 5.60 ppb, 37% of the 15 ppb federal action level. The action level is a treatment trigger, not a legal maximum, and it is measured across sampled taps rather than at any single home. Copper reached the action level here; a copper figure appears in SDWIS only when a system triggers it.

Contaminant Violations (2015–Present)

ContaminantTypeMeasuredLimitPeriodStatus
Nitrate MONITORING AND REPORTING — 10 mg/L 2022 Resolved
TTHM MCL EXCEEDANCE 81.6 UG/L 0.080 mg/L 2021 Resolved
TTHM MCL EXCEEDANCE 90.8 UG/L 0.080 mg/L 2021 Resolved
TTHM MCL EXCEEDANCE 90.5 UG/L 0.080 mg/L 2020 Resolved
TTHM MCL EXCEEDANCE 83.1 UG/L 0.080 mg/L 2020 Resolved
TTHM MCL EXCEEDANCE 82 UG/L 0.080 mg/L 2020 Resolved
Arsenic MONITORING AND REPORTING — 0.010 mg/L 2020 Resolved
Barium MONITORING AND REPORTING — 2 mg/L 2020 Resolved
Cadmium MONITORING AND REPORTING — 0.005 mg/L 2020 Resolved
Chromium MONITORING AND REPORTING — 0.1 mg/L 2020 Resolved
CYANIDE MONITORING AND REPORTING — 0.2 mg/L 2020 Resolved
Fluoride MONITORING AND REPORTING — 4.0 mg/L 2020 Resolved
Mercury MONITORING AND REPORTING — 0.002 mg/L 2020 Resolved
Nickel MONITORING AND REPORTING — — 2020 Resolved
Antimony, Total MONITORING AND REPORTING — 0.006 mg/L 2020 Resolved
Beryllium, Total MONITORING AND REPORTING — 0.004 mg/L 2020 Resolved
Thallium, Total MONITORING AND REPORTING — 0.002 mg/L 2020 Resolved
Selenium MONITORING AND REPORTING — 0.05 mg/L 2020 Resolved
Nitrate MONITORING AND REPORTING — 10 mg/L 2020 Resolved
Public Notice OTHER — — 2018 Resolved
Surface Water Treatment Rule TREATMENT TECHNIQUE — — 2018 Resolved
Revised Total Coliform Rule MONITORING FAILURE — — 2017 Resolved
Nitrate MONITORING AND REPORTING — 10 mg/L 2017 Resolved
Arsenic MONITORING AND REPORTING — 0.010 mg/L 2017 Resolved
Barium MONITORING AND REPORTING — 2 mg/L 2017 Resolved
Cadmium MONITORING AND REPORTING — 0.005 mg/L 2017 Resolved
Chromium MONITORING AND REPORTING — 0.1 mg/L 2017 Resolved
CYANIDE MONITORING AND REPORTING — 0.2 mg/L 2017 Resolved
Fluoride MONITORING AND REPORTING — 4.0 mg/L 2017 Resolved
Mercury MONITORING AND REPORTING — 0.002 mg/L 2017 Resolved
Nickel MONITORING AND REPORTING — — 2017 Resolved
Antimony, Total MONITORING AND REPORTING — 0.006 mg/L 2017 Resolved
Beryllium, Total MONITORING AND REPORTING — 0.004 mg/L 2017 Resolved
Thallium, Total MONITORING AND REPORTING — 0.002 mg/L 2017 Resolved
Selenium MONITORING AND REPORTING — 0.05 mg/L 2017 Resolved
Public Notice OTHER — — 2016 Resolved
Surface Water Treatment Rule TREATMENT TECHNIQUE — — 2016 Resolved
TTHM MCL EXCEEDANCE 101.7 UG/L 0.080 mg/L 2016 Resolved
TTHM MCL EXCEEDANCE 80.8 UG/L 0.080 mg/L 2016 Resolved
Nitrate MONITORING AND REPORTING — 10 mg/L 2016 Resolved
Consumer Confidence Rule OTHER — — 2015 Resolved
Total Haloacetic Acids (HAA5) MONITORING AND REPORTING — 0.060 mg/L 2015 Resolved
TTHM MONITORING AND REPORTING — 0.080 mg/L 2015 Resolved
Understanding violation types MCL violations mean a contaminant exceeded the federal maximum limit — the most serious type.
TT (Treatment Technique) violations mean required treatment procedures weren't followed, but don't necessarily mean contamination occurred.

Violation History

43 violations are on record since 2015, of which 9 were health-based. All have been resolved and none remain open.

About the Main Water System

Utility Whitehall Village
PWSID NY5700124
Water source Surface water — Drawn from surface water — SDWIS source code SW
Population served 2,363
Service connections 1,432
Systems serving this area 1
Regulator State primacy agency
Data through 2026 Q2 — EPA SDWIS

Frequently Asked Questions

Is Whitehall tap water safe to drink? ▼
No federal limit is exceeded on record. No violations are currently open. Lead is 5.60 ppb, 37% of the action level.
Does Whitehall water have PFAS? ▼
This system has never been sampled for PFAS. EPA's national monitoring covered systems serving 3,300 people or more, so no results exist — which is not evidence that none is present.
Who supplies water to Whitehall? ▼
Whitehall Village (PWSID NY5700124). Surface water. Drawn from surface water — SDWIS source code SW
When was this system last inspected? ▼
It was last inspected on 2022-12-08. No significant deficiencies were recorded.

What Should Whitehall Residents Do?

1
Consider a filter certified for lead
Look for NSF/ANSI 53 certification for lead reduction.
2
Check for a lead service line
Lead reaches tap water mainly through service lines and household plumbing. Suppliers now publish an inventory identifying lead lines.
3
Flush before drinking
If water has sat in pipes more than six hours, run the cold tap for two minutes before drinking or cooking.

Nearby Cities in New York

Kingsbury, Ny Tap Water Quality 2026 Washington Fort Edward, Ny Tap Water Quality 2026 Washington Granville, Ny Tap Water Quality 2026 Washington Fort Ann, Ny Tap Water Quality 2026 Washington Greenwich, Ny Tap Water Quality 2026 Washington Greenwich, Ny Tap Water Quality 2026 Washington