Green, NJ Tap Water Quality 2026

Water quality report for Green, NJ — PFAS, lead and copper results, violation history and state inspection findings from EPA SDWIS.

A look at Green's drinking water using EPA enforcement records: violations, lead and copper results, PFAS sampling and state inspection findings.

Main Utility: Aqua Nj - Tranquility Springs PWSID: NJ1908001 Updated: 2026 Q2
🚨

1 violation currently open

Lead was not detected. PFAS has never been sampled at this system.

D

Green earns a D for water quality

Graded on violations and lead, with state inspection findings. PFAS not tested.

Lead: not detected
PFAS never sampled at this system
20 violations since 2015, 1 health-based
1 violation currently open
Green's lead level vs. all New Jersey community water systems
0 ppb5 ppb10 ppb15 ppb
Lead level: Not detected — 0% of the federal action level
✓ Lower lead than % of New Jersey utilities
Population Served
521
~46 connections
Water Source
Surface water
Groundwater under the direct influence of surface water — SDWIS source code GU
Active Violations
1
1 open of 20 since 2015

Lead & Copper Testing

Lead (Pb)
90th percentile of tap samples collected across the distribution system
0% of EPA action level
Not detected
Action level: 15 ppb
Copper (Cu)
90th percentile of tap samples. SDWIS reports a copper figure only when a system exceeds the action level, so any value here is an exceedance.
123.1% of EPA action level
1,600 ppb
Action level: 1,300 ppb
Lead was not detected at the 90th percentile — the result fell below the laboratory detection limit. That is not the same as an absence of lead in every tap, and older homes with lead service lines can still show higher readings. Copper reached the action level here; a copper figure appears in SDWIS only when a system triggers it.

Contaminant Violations (2015–Present)

ContaminantTypeMeasuredLimitPeriodStatus
Surface Water Treatment Rule MONITORING AND REPORTING — — 2025 Resolved
Surface Water Treatment Rule MONITORING AND REPORTING — — 2025 Resolved
Lead and Copper Rule TREATMENT TECHNIQUE — TT 2025 Unaddressed
Lead and Copper Rule MONITORING AND REPORTING — TT 2025 Unaddressed
Lead and Copper Rule MONITORING AND REPORTING — TT 2025 Resolved
Lead and Copper Rule MONITORING AND REPORTING — TT 2024 Resolved
Lead and Copper Rule MONITORING AND REPORTING — TT 2023 Resolved
Lead and Copper Rule MONITORING AND REPORTING — TT 2021 Resolved
TTHM MONITORING AND REPORTING — 0.080 mg/L 2021 Resolved
Lead and Copper Rule MONITORING AND REPORTING — TT 2020 Resolved
Revised Total Coliform Rule REPORTING FAILURE — — 2019 Resolved
Surface Water Treatment Rule MONITORING AND REPORTING — — 2019 Resolved
Surface Water Treatment Rule MONITORING AND REPORTING — — 2017 Resolved
Gross Alpha, Excl. Radon and U MONITORING AND REPORTING — 15 pCi/L 2017–2025 Resolved
Combined Uranium MONITORING AND REPORTING — 30 ug/L 2017–2025 Resolved
Combined Radium (-226 and -228) MONITORING AND REPORTING — 5 pCi/L 2017–2025 Resolved
Radium-226 MONITORING AND REPORTING — — 2017–2025 Resolved
Radium-228 MONITORING AND REPORTING — — 2017–2025 Resolved
Surface Water Treatment Rule MONITORING AND REPORTING — — 2016 Resolved
Surface Water Treatment Rule MONITORING AND REPORTING — — 2015 Resolved
Understanding violation types MCL violations mean a contaminant exceeded the federal maximum limit — the most serious type.
TT (Treatment Technique) violations mean required treatment procedures weren't followed, but don't necessarily mean contamination occurred.

Violation History

1 violation remains open, out of 20 recorded since 2015 (1 health-based).

About the Main Water System

Utility Aqua Nj - Tranquility Springs
PWSID NJ1908001
Water source Surface water — Groundwater under the direct influence of surface water — SDWIS source code GU
Population served 521
Service connections 46
Systems serving this area 2
Regulator State primacy agency
Data through 2026 Q2 — EPA SDWIS

Frequently Asked Questions

Is Green tap water safe to drink? ▼
No federal limit is exceeded on record. 1 violation(s) remain open.
Does Green water have PFAS? ▼
This system has never been sampled for PFAS. EPA's national monitoring covered systems serving 3,300 people or more, so no results exist — which is not evidence that none is present.
Who supplies water to Green? ▼
Aqua Nj - Tranquility Springs (PWSID NJ1908001), one of 2 systems serving this area. Surface water. Groundwater under the direct influence of surface water — SDWIS source code GU
When was this system last inspected? ▼
It was last inspected on 2025-08-28. No significant deficiencies were recorded.

What Should Green Residents Do?

1
Read your annual water report
Your supplier publishes a Consumer Confidence Report each July covering the prior year.
2
Check for a lead service line
Lead reaches tap water mainly through service lines and household plumbing. Suppliers now publish an inventory identifying lead lines.
3
Follow the open violation
This system has an unresolved violation. Contact the supplier for its corrective-action schedule.

Nearby Cities in New Jersey

Sparta, Nj Tap Water Quality 2026 Sussex Hopatcong, Nj Tap Water Quality 2026 Sussex Lake Mohawk, Nj Tap Water Quality 2026 Sussex Newton, Nj Tap Water Quality 2026 Sussex Franklin, Nj Tap Water Quality 2026 Sussex Stanhope, Nj Tap Water Quality 2026 Sussex