Lead is 1.11 ppb, 7% of the action level and no violations are open. PFAS has never been sampled at this system.
Graded on violations and lead, with state inspection findings. PFAS not tested.
| Contaminant | Type | Measured | Limit | Period | Status |
|---|---|---|---|---|---|
| Groundwater Rule | MONITORING AND REPORTING | — | — | 2026 | Resolved |
| LEAD AND COPPER RULE REVISIONS | REPORTING FAILURE | — | — | 2025 | Unaddressed |
| Groundwater Rule | MONITORING AND REPORTING | — | — | 2025 | Resolved |
| Nitrate-Nitrite | MONITORING AND REPORTING | — | — | 2025 | Resolved |
| Combined Radium (-226 and -228) | MCL EXCEEDANCE | 6.65 PCI/L | 5 pCi/L | 2024–2025 | Resolved |
| Groundwater Rule | MONITORING AND REPORTING | — | — | 2024 | Resolved |
| Combined Radium (-226 and -228) | MCL EXCEEDANCE | 8.5 PCI/L | 5 pCi/L | 2024–2025 | Resolved |
| Combined Radium (-226 and -228) | MCL EXCEEDANCE | 9.43 PCI/L | 5 pCi/L | 2024–2025 | Resolved |
| Combined Radium (-226 and -228) | MCL EXCEEDANCE | 7.28 PCI/L | 5 pCi/L | 2024 | Resolved |
| Groundwater Rule | MONITORING AND REPORTING | — | — | 2023 | Resolved |
| Combined Radium (-226 and -228) | MCL EXCEEDANCE | 5.83 PCI/L | 5 pCi/L | 2019–2020 | Resolved |
| Combined Radium (-226 and -228) | MCL EXCEEDANCE | 7.2 PCI/L | 5 pCi/L | 2019–2020 | Resolved |
| Combined Radium (-226 and -228) | MCL EXCEEDANCE | 8.65 PCI/L | 5 pCi/L | 2019–2020 | Resolved |
| Combined Radium (-226 and -228) | MCL EXCEEDANCE | 9.53 PCI/L | 5 pCi/L | 2019 | Resolved |
| Combined Radium (-226 and -228) | MCL EXCEEDANCE | 10.38 PCI/L | 5 pCi/L | 2018–2019 | Resolved |
| Combined Radium (-226 and -228) | MCL EXCEEDANCE | 10.53 PCI/L | 5 pCi/L | 2018–2019 | Resolved |
| Gross Alpha, Excl. Radon and U | MCL EXCEEDANCE | 18.55 PCI/L | 15 pCi/L | 2018–2019 | Resolved |
| Combined Radium (-226 and -228) | MCL EXCEEDANCE | 10.95 PCI/L | 5 pCi/L | 2018–2019 | Resolved |
| Gross Alpha, Excl. Radon and U | MCL EXCEEDANCE | 20.9 PCI/L | 15 pCi/L | 2018 | Resolved |
| Combined Radium (-226 and -228) | MCL EXCEEDANCE | 11.28 PCI/L | 5 pCi/L | 2018 | Resolved |
| Gross Alpha, Excl. Radon and U | MCL EXCEEDANCE | 20.81 PCI/L | 15 pCi/L | 2017–2018 | Resolved |
| Combined Radium (-226 and -228) | MCL EXCEEDANCE | 11.2 PCI/L | 5 pCi/L | 2017–2018 | Resolved |
| Gross Alpha, Excl. Radon and U | MCL EXCEEDANCE | 19.44 PCI/L | 15 pCi/L | 2017–2018 | Resolved |
| Combined Radium (-226 and -228) | MCL EXCEEDANCE | 10.18 PCI/L | 5 pCi/L | 2017–2018 | Resolved |
| Gross Alpha, Excl. Radon and U | MCL EXCEEDANCE | 18.13 PCI/L | 15 pCi/L | 2017–2018 | Resolved |
| Combined Radium (-226 and -228) | MCL EXCEEDANCE | 10.05 PCI/L | 5 pCi/L | 2017–2018 | Resolved |
| Gross Alpha, Excl. Radon and U | MCL EXCEEDANCE | 17.27 PCI/L | 15 pCi/L | 2017 | Resolved |
| Combined Radium (-226 and -228) | MCL EXCEEDANCE | 9.6 PCI/L | 5 pCi/L | 2017 | Resolved |
| Gross Alpha, Excl. Radon and U | MCL EXCEEDANCE | 15.68 PCI/L | 15 pCi/L | 2016–2017 | Resolved |
| Combined Radium (-226 and -228) | MCL EXCEEDANCE | 10.03 PCI/L | 5 pCi/L | 2016–2017 | Resolved |
| Gross Alpha, Excl. Radon and U | MCL EXCEEDANCE | 16.71 PCI/L | 15 pCi/L | 2016–2017 | Resolved |
| Combined Radium (-226 and -228) | MCL EXCEEDANCE | 11.03 PCI/L | 5 pCi/L | 2016–2017 | Resolved |
| Gross Alpha, Excl. Radon and U | MCL EXCEEDANCE | 16.06 PCI/L | 15 pCi/L | 2016–2017 | Resolved |
| Combined Radium (-226 and -228) | MCL EXCEEDANCE | 11.18 PCI/L | 5 pCi/L | 2016–2017 | Resolved |
| Gross Alpha, Excl. Radon and U | MCL EXCEEDANCE | 17.36 PCI/L | 15 pCi/L | 2016 | Resolved |
| Combined Radium (-226 and -228) | MCL EXCEEDANCE | 11.73 PCI/L | 5 pCi/L | 2016 | Resolved |