Water quality report for Shelby, MN — PFAS, lead and copper results, violation history and state inspection findings from EPA SDWIS.
A look at Shelby's drinking water using EPA enforcement records: violations, lead and copper results, PFAS sampling and state inspection findings.
Lead is 6.00 ppb, 40% of the action level and no violations are open. No PFAS was detected.
Graded on violations, lead, and PFAS, with state inspection findings.
| Contaminant | Type | Measured | Limit | Period | Status |
|---|---|---|---|---|---|
| Combined Radium (-226 and -228) | MCL EXCEEDANCE | 2 PCI/L | 5 pCi/L | 2024 | Archived |
| Combined Radium (-226 and -228) | MCL EXCEEDANCE | 4.1 PCI/L | 5 pCi/L | 2024 | Archived |
| Combined Radium (-226 and -228) | MCL EXCEEDANCE | 5.1 PCI/L | 5 pCi/L | 2024 | Archived |
| Combined Radium (-226 and -228) | MCL EXCEEDANCE | 8 PCI/L | 5 pCi/L | 2023 | Archived |
| Combined Radium (-226 and -228) | MCL EXCEEDANCE | 8.3 PCI/L | 5 pCi/L | 2023 | Archived |
| Combined Radium (-226 and -228) | MCL EXCEEDANCE | 4.3 PCI/L | 5 pCi/L | 2023 | Archived |
| Combined Radium (-226 and -228) | MCL EXCEEDANCE | 6 PCI/L | 5 pCi/L | 2023 | Archived |
| Combined Radium (-226 and -228) | MCL EXCEEDANCE | 6 PCI/L | 5 pCi/L | 2022 | Archived |
| Combined Radium (-226 and -228) | MCL EXCEEDANCE | 5.3 PCI/L | 5 pCi/L | 2022 | Archived |
| Combined Radium (-226 and -228) | MCL EXCEEDANCE | 5.6 PCI/L | 5 pCi/L | 2022 | Resolved |
| Total Haloacetic Acids (HAA5) | MONITORING AND REPORTING | — | 0.060 mg/L | 2021 | Resolved |
| TTHM | MONITORING AND REPORTING | — | 0.080 mg/L | 2021 | Resolved |
| Coliform (TCR) | MCL EXCEEDANCE | — | 5% of samples | 2015 | Resolved |