Water quality report for Morocco, IN — PFAS, lead and copper results, violation history and state inspection findings from EPA SDWIS.
A look at Morocco's drinking water using EPA enforcement records: violations, lead and copper results, PFAS sampling and state inspection findings.
Lead is 1.00 ppb, 7% of the action level and no violations are open. PFAS has never been sampled at this system.
Graded on violations and lead, with state inspection findings. PFAS not tested.
| Contaminant | Type | Measured | Limit | Period | Status |
|---|---|---|---|---|---|
| LEAD AND COPPER RULE REVISIONS | REPORTING FAILURE | — | — | 2025 | Unaddressed |
| Consumer Confidence Rule | OTHER | — | — | 2025 | Resolved |
| Gross Alpha, Excl. Radon and U | MONITORING AND REPORTING | — | 15 pCi/L | 2024 | Resolved |
| Radium-226 | MONITORING AND REPORTING | — | — | 2024 | Resolved |
| Radium-228 | MONITORING AND REPORTING | — | — | 2024 | Resolved |
| Revised Total Coliform Rule | REPORTING FAILURE | — | — | 2024 | Resolved |
| Revised Total Coliform Rule | REPORTING FAILURE | — | — | 2021 | Resolved |
| TTHM | MCL EXCEEDANCE | 84 UG/L | 0.080 mg/L | 2020 | Resolved |
| TTHM | MCL EXCEEDANCE | 82 UG/L | 0.080 mg/L | 2020 | Resolved |
| Lead and Copper Rule | MONITORING AND REPORTING | — | TT | 2018 | Resolved |
| Lead and Copper Rule | MONITORING AND REPORTING | — | TT | 2016 | Resolved |
| Lead and Copper Rule | MONITORING AND REPORTING | — | TT | 2016 | Resolved |