States ›California ›Napa County ›Moskowite Corner

Moskowite Corner, CA Tap Water Quality 2026

Water quality report for Moskowite Corner, CA — PFAS, lead and copper results, violation history and state inspection findings from EPA SDWIS.

A look at Moskowite Corner's drinking water using EPA enforcement records: violations, lead and copper results, PFAS sampling and state inspection findings.

Main Utility: Capell Valley Estates PWSID: CA2800543 Updated: 2026 Q2
🚨

1 violation currently open

Lead is 3.30 ppb, 22% of the action level. PFAS has never been sampled at this system.

C

Moskowite Corner earns a C for water quality

Graded on violations and lead, with state inspection findings. PFAS not tested.

Lead: 3.30 ppb — 22% of the federal action level
PFAS never sampled at this system
4 violations since 2015, 2 health-based
1 violation currently open
Moskowite Corner's lead level vs. all California community water systems
0 ppb5 ppb10 ppb15 ppb
Lead level: 3.30 ppb — 22% of the federal action level
✓ Lower lead than 31% of California utilities
Population Served
159
~63 connections
Water Source
Surface water
Drawn from surface water — SDWIS source code SW
Active Violations
1
1 open of 4 since 2015

Lead & Copper Testing

Lead (Pb)
90th percentile of tap samples collected across the distribution system
22% of EPA action level
3.30 ppb
Action level: 15 ppb
The 90th-percentile lead result is 3.30 ppb, 22% of the 15 ppb federal action level. The action level is a treatment trigger, not a legal maximum, and it is measured across sampled taps rather than at any single home.

Contaminant Violations (2015–Present)

ContaminantTypeMeasuredLimitPeriodStatus
LEAD AND COPPER RULE REVISIONS TREATMENT TECHNIQUE — — 2024 Unaddressed
LEAD AND COPPER RULE REVISIONS REPORTING FAILURE — — 2024 Unaddressed
Lead and Copper Rule MONITORING AND REPORTING — TT 2018 Resolved
TTHM MCL EXCEEDANCE 0.085 MG/L 0.080 mg/L 2015 Resolved
Understanding violation types MCL violations mean a contaminant exceeded the federal maximum limit — the most serious type.
TT (Treatment Technique) violations mean required treatment procedures weren't followed, but don't necessarily mean contamination occurred.

Violation History

1 violation remains open, out of 4 recorded since 2015 (2 health-based).

About the Main Water System

Utility Capell Valley Estates
PWSID CA2800543
Water source Surface water — Drawn from surface water — SDWIS source code SW
Population served 159
Service connections 63
Systems serving this area 1
Regulator State primacy agency
Data through 2026 Q2 — EPA SDWIS

Frequently Asked Questions

Is Moskowite Corner tap water safe to drink? ▼
No federal limit is exceeded on record. 1 violation(s) remain open. Lead is 3.30 ppb, 22% of the action level.
Does Moskowite Corner water have PFAS? ▼
This system has never been sampled for PFAS. EPA's national monitoring covered systems serving 3,300 people or more, so no results exist — which is not evidence that none is present.
Who supplies water to Moskowite Corner? ▼
Capell Valley Estates (PWSID CA2800543). Surface water. Drawn from surface water — SDWIS source code SW
When was this system last inspected? ▼
It was last inspected on 2025-06-17. No significant deficiencies were recorded.

What Should Moskowite Corner Residents Do?

1
Read your annual water report
Your supplier publishes a Consumer Confidence Report each July covering the prior year.
2
Check for a lead service line
Lead reaches tap water mainly through service lines and household plumbing. Suppliers now publish an inventory identifying lead lines.
3
Follow the open violation
This system has an unresolved violation. Contact the supplier for its corrective-action schedule.

Nearby Cities in California

Napa, Ca Tap Water Quality 2026 Napa American Canyon, Ca Tap Water Quality 2026 Napa St. Helena, Ca Tap Water Quality 2026 Napa Calistoga, Ca Tap Water Quality 2026 Napa Yountville, Ca Tap Water Quality 2026 Napa Angwin, Ca Tap Water Quality 2026 Napa