States ›Arkansas ›Lee County ›Aubrey

Aubrey, AR Tap Water Quality 2026

Water quality report for Aubrey, AR — PFAS, lead and copper results, violation history and state inspection findings from EPA SDWIS.

A look at Aubrey's drinking water using EPA enforcement records: violations, lead and copper results, PFAS sampling and state inspection findings.

Main Utility: Lee County Water Association PWSID: AR0000313 Updated: 2026 Q2
✅

No federal limits exceeded on record

Lead is 2.00 ppb, 13% of the action level and no violations are open. PFAS was sampled but not enough times for a compliance determination.

C

Aubrey earns a C for water quality

Graded on violations and lead, with state inspection findings. PFAS not tested.

Lead: 2.00 ppb — 13% of the federal action level
PFAS sampled, too few results to judge
70 violations since 2015, 49 health-based
No violations currently open
Aubrey's lead level vs. all Arkansas community water systems
0 ppb5 ppb10 ppb15 ppb
Lead level: 2.00 ppb — 13% of the federal action level
✓ Lower lead than 57% of Arkansas utilities
Population Served
108
~1632 connections
Water Source
Groundwater
Purchased groundwater from another system — SDWIS source code GWP
Active Violations
0
70 since 2015, all resolved

Lead & Copper Testing

Lead (Pb)
90th percentile of tap samples collected across the distribution system
13% of EPA action level
2.00 ppb
Action level: 15 ppb
Copper (Cu)
90th percentile of tap samples. SDWIS reports a copper figure only when a system exceeds the action level, so any value here is an exceedance.
116.9% of EPA action level
1,520 ppb
Action level: 1,300 ppb
The 90th-percentile lead result is 2.00 ppb, 13% of the 15 ppb federal action level. The action level is a treatment trigger, not a legal maximum, and it is measured across sampled taps rather than at any single home. Copper reached the action level here; a copper figure appears in SDWIS only when a system triggers it.

Contaminant Violations (2015–Present)

ContaminantTypeMeasuredLimitPeriodStatus
TTHM MCL EXCEEDANCE 81 UG/L 0.080 mg/L 2024 Archived
TTHM MCL EXCEEDANCE 91 UG/L 0.080 mg/L 2024 Archived
TTHM MCL EXCEEDANCE 96 UG/L 0.080 mg/L 2024 Archived
TTHM MCL EXCEEDANCE 98 UG/L 0.080 mg/L 2023 Archived
TTHM MCL EXCEEDANCE 115 UG/L 0.080 mg/L 2023 Archived
TTHM MCL EXCEEDANCE 91 UG/L 0.080 mg/L 2023 Archived
TTHM MCL EXCEEDANCE 98 UG/L 0.080 mg/L 2023 Archived
TTHM MCL EXCEEDANCE 88 UG/L 0.080 mg/L 2023 Archived
TTHM MCL EXCEEDANCE 91 UG/L 0.080 mg/L 2023 Archived
TTHM MCL EXCEEDANCE 86 UG/L 0.080 mg/L 2023 Archived
TTHM MCL EXCEEDANCE 88 UG/L 0.080 mg/L 2022 Archived
TTHM MCL EXCEEDANCE 82 UG/L 0.080 mg/L 2022 Archived
TTHM MCL EXCEEDANCE 81 UG/L 0.080 mg/L 2021 Archived
TTHM MCL EXCEEDANCE 86 UG/L 0.080 mg/L 2021 Archived
TTHM MCL EXCEEDANCE 83 UG/L 0.080 mg/L 2021 Archived
TTHM MCL EXCEEDANCE 81 UG/L 0.080 mg/L 2021 Archived
TTHM MCL EXCEEDANCE 87 UG/L 0.080 mg/L 2021 Archived
TTHM MCL EXCEEDANCE 86 UG/L 0.080 mg/L 2021 Archived
TTHM MCL EXCEEDANCE 93 UG/L 0.080 mg/L 2020 Archived
TTHM MCL EXCEEDANCE 94 UG/L 0.080 mg/L 2020 Archived
Public Notice OTHER — — 2020 Resolved
TTHM MCL EXCEEDANCE 97 UG/L 0.080 mg/L 2020 Archived
TTHM MCL EXCEEDANCE 94 UG/L 0.080 mg/L 2020 Archived
Revised Total Coliform Rule MONITORING FAILURE — — 2020 Archived
Revised Total Coliform Rule MONITORING FAILURE — — 2020 Archived
Revised Total Coliform Rule REPORTING FAILURE — — 2020 Addressed
Public Notice OTHER — — 2020 Resolved
TTHM MCL EXCEEDANCE 97 UG/L 0.080 mg/L 2020 Archived
TTHM MCL EXCEEDANCE 88 UG/L 0.080 mg/L 2020 Archived
TTHM MCL EXCEEDANCE 99 UG/L 0.080 mg/L 2020 Archived
TTHM MCL EXCEEDANCE 93 UG/L 0.080 mg/L 2020 Archived
Public Notice OTHER — — 2019 Resolved
Public Notice OTHER — — 2019 Resolved
TTHM MCL EXCEEDANCE 97 UG/L 0.080 mg/L 2019 Archived
TTHM MCL EXCEEDANCE 89 UG/L 0.080 mg/L 2019 Archived
Revised Total Coliform Rule TREATMENT TECHNIQUE — — 2019 Resolved
TTHM MCL EXCEEDANCE 88 UG/L 0.080 mg/L 2019 Archived
TTHM MCL EXCEEDANCE 96 UG/L 0.080 mg/L 2019 Archived
Public Notice OTHER — — 2019 Resolved
TTHM MCL EXCEEDANCE 89 UG/L 0.080 mg/L 2019 Archived
TTHM MCL EXCEEDANCE 95 UG/L 0.080 mg/L 2019 Archived
Revised Total Coliform Rule REPORTING FAILURE — — 2019 Resolved
Public Notice OTHER — — 2019 Resolved
Revised Total Coliform Rule MONITORING FAILURE — — 2019 Resolved
TTHM MCL EXCEEDANCE 90 UG/L 0.080 mg/L 2019 Archived
Public Notice OTHER — — 2018 Resolved
TTHM MCL EXCEEDANCE 88 UG/L 0.080 mg/L 2018 Archived
Public Notice OTHER — — 2018 Resolved
TTHM MCL EXCEEDANCE 95 UG/L 0.080 mg/L 2018 Archived
Consumer Confidence Rule OTHER — — 2018 Resolved
TTHM MCL EXCEEDANCE 91 UG/L 0.080 mg/L 2018 Archived
Public Notice OTHER — — 2018 Resolved
Public Notice OTHER — — 2018 Resolved
TTHM MCL EXCEEDANCE 88 UG/L 0.080 mg/L 2018 Archived
Public Notice OTHER — — 2017 Resolved
TTHM MCL EXCEEDANCE 90 UG/L 0.080 mg/L 2017 Archived
Public Notice OTHER — — 2017 Resolved
TTHM MCL EXCEEDANCE 86 UG/L 0.080 mg/L 2017 Archived
Public Notice OTHER — — 2017 Resolved
TTHM MCL EXCEEDANCE 88 UG/L 0.080 mg/L 2017 Archived
TTHM MCL EXCEEDANCE 92 UG/L 0.080 mg/L 2017 Archived
Public Notice OTHER — — 2016 Resolved
TTHM MCL EXCEEDANCE 88 UG/L 0.080 mg/L 2016 Archived
Public Notice OTHER — — 2016 Resolved
TTHM MCL EXCEEDANCE 87 UG/L 0.080 mg/L 2016 Archived
TTHM MCL EXCEEDANCE 86 UG/L 0.080 mg/L 2016 Archived
TTHM MCL EXCEEDANCE 90 UG/L 0.080 mg/L 2016 Archived
TTHM MCL EXCEEDANCE 88 UG/L 0.080 mg/L 2016 Archived
TTHM MCL EXCEEDANCE 86 UG/L 0.080 mg/L 2015 Archived
TTHM MCL EXCEEDANCE 85 UG/L 0.080 mg/L 2015 Archived
Understanding violation types MCL violations mean a contaminant exceeded the federal maximum limit — the most serious type.
TT (Treatment Technique) violations mean required treatment procedures weren't followed, but don't necessarily mean contamination occurred.

Violation History

70 violations are on record since 2015, of which 49 were health-based. All have been resolved and none remain open.

About the Main Water System

Utility Lee County Water Association
PWSID AR0000313
Water source Groundwater — Purchased groundwater from another system — SDWIS source code GWP
Population served 108
Service connections 1,632
Systems serving this area 1
Regulator State primacy agency
Data through 2026 Q2 — EPA SDWIS

Frequently Asked Questions

Is Aubrey tap water safe to drink? ▼
No federal limit is exceeded on record. No violations are currently open. Lead is 2.00 ppb, 13% of the action level.
Does Aubrey water have PFAS? ▼
It was sampled, but no sampling point had enough results for a compliance determination.
Who supplies water to Aubrey? ▼
Lee County Water Association (PWSID AR0000313). Groundwater. Purchased groundwater from another system — SDWIS source code GWP
When was this system last inspected? ▼
It was last inspected on 2025-05-28. No significant deficiencies were recorded.

What Should Aubrey Residents Do?

1
Read your annual water report
Your supplier publishes a Consumer Confidence Report each July covering the prior year.
2
Check for a lead service line
Lead reaches tap water mainly through service lines and household plumbing. Suppliers now publish an inventory identifying lead lines.
3
Flush before drinking
If water has sat in pipes more than six hours, run the cold tap for two minutes before drinking or cooking.

Nearby Cities in Arkansas

Marianna, Ar Tap Water Quality 2026 Lee Moro, Ar Tap Water Quality 2026 Lee Rondo, Ar Tap Water Quality 2026 Lee Haynes, Ar Tap Water Quality 2026 Lee LaGrange, Ar Tap Water Quality 2026 Lee